Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Braz. dent. j ; 28(3): 385-390, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888642

ABSTRACT

Abstract This study aimed to assess the performance of surgeons in determining the amount of graft material required for maxillary sinus floor augmentation in a preoperative analysis using cone-beam computed tomography images. A convenience sample of 10 retrospective CBCT exams (i-CAT®) was selected. Scans of the posterior maxilla area with an absence of at least one tooth and residual alveolar bone with an up to 5 mm height were used. Templates (n=20) contained images of representative cross-sections in multiplanar view. Ten expert surgeons voluntarily participated as appraisers of the templates for grafting surgical planning of a 10 mm long implant. Appraisers could choose a better amount of graft material using scores: 0) when considered grafting unnecessary, 1) for 0.25 g in graft material, 2) for 0.50 g, 3) for 1.00 g and 4) for 1.50 g or more. Reliability of the response pattern was analyzed using Cronbach's a. Wilcoxon and Mann-Whitney tests were performed to compare scores. Regression analysis was performed to evaluate whether the volume of sinuses (mm3) influenced the choose of scores. In the reliability analysis, all values were low and the score distribution was independent of the volume of the maxillary sinuses (p>0.05), which did not influence choosing the amount of graft material. Surgeons were unreliable to determine the best amount of graft material for the maxillary sinus floor augmentation using only CBCT images. Surgeons require auxiliary diagnostic tools to measure the volume associated to CBCT exams in order to perform better.


Resumo O objetivo deste estudo foi avaliar o desempenho dos cirurgiões na determinação da quantidade de material de enxerto necessária para a elevação do assoalho do seio maxilar em uma análise pré-operatória, utilizando imagens de tomografia computadorizada de feixe cônico. Foi selecionada uma amostra de conveniência de 10 exames retrospectivos CBCT (i-CAT®). Os exames foram da área da maxila posterior que possuíam ausência de pelo menos um dente e com osso alveolar residual de altura igual ou inferior a 5 mm. Os templates (n=20) continham imagens de secções transversais representativas numa vista multiplanar. Dez experientes cirurgiões voluntariamente participaram como avaliadores dos templates para o planejamento cirúrgico de enxerto para um implante de 10 mm de comprimento. Os avaliadores escolheram a melhor quantidade de material de enxerto usando os escores: 0) quando o enxerto era desnecessário, 1) para 0,25 g de enxerto, 2) para 0,50 g, 3) para 1,00 g, e 4) para 1,50 g ou mais. A confiabilidade do padrão de resposta foi analisada utilizando a a de Cronbach. Os testes de Wilcoxon e Mann-Whitney foram utilizados para comparar os escores. A análise de regressão foi realizada para avaliar se o volume dos seios (mm3) influenciou a escolha dos escores. Na análise de confiabilidade, todos os valores foram baixos e a distribuição dos escores foi independente do volume dos seios maxilares (p>0,05), o que não influenciou a escolha da quantidade de material de enxerto. Os cirurgiões apresentaram falta de confiabilidade ao determinar a melhor quantidade de material de enxerto para o aumento do assoalho do seio maxilar utilizando somente as imagens de TCFC. Assim, os cirurgiões necessitam de ferramentas de diagnóstico auxiliares para mensuração de volume associada à TCFC para um melhor desempenho.


Subject(s)
Humans , Adult , Middle Aged , Clinical Competence , Cone-Beam Computed Tomography/methods , Orthognathic Surgical Procedures/methods , Sinus Floor Augmentation/methods , Surgery, Oral , Maxillary Sinus/diagnostic imaging , Maxillary Sinus/surgery , Reproducibility of Results , Retrospective Studies
2.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Article in English | LILACS | ID: lil-777175

ABSTRACT

Three-dimensional imaging modalities have been reported to be more accurate than panoramic radiographs (PR) for the assessment of bone components of the temporomandibular joint (TMJ). No exact prior information is available that demonstrates which specific limitations occur in terms of TMJ diagnosis when using PR for this purpose. This study aimed to assess the clinical validity of digital panoramic radiography (DPR) when diagnosing morphological disorders of the TMJ using cone-beam computed tomography (CBCT) images as the gold standard. A sample composed of TMJ images (N = 848), including 212 DPR and 212 CBCT images obtained from the same patient, was used to assess any morphological changes in the TMJ. Four appraisers diagnosed all of the DPR images, whereas the CBCT images were used to establish the gold standard. The reliability of each appraiser’s response pattern was analyzed using the Kappa test (κ), and diagnostic tests were performed to assess each appraiser’s performance using a significance level setting of 5% (α = 0.05). Reliability of each appraiser’s response pattern compared to the gold standard ranged from a slight-to-moderate agreement (0.18 ≤ κ ≤ 0.45); and among the different appraisers, the response pattern showed a fair agreement (0.22 ≤ κ ≤ 0.39). Diagnostic tests showed a wide range among the different possible morphological changes diagnosed. DPR does not have validity when diagnosing morphological changes in the TMJ; it underestimates the radiological findings with higher prevalence, and thus, it cannot be used effectively as a diagnostic tool for bone components within this region.


Subject(s)
Adolescent , Adult , Aged , Humans , Middle Aged , Young Adult , Cone-Beam Computed Tomography/standards , Radiography, Dental, Digital/standards , Radiography, Panoramic/standards , Temporomandibular Joint Disorders , Brazil/epidemiology , Cone-Beam Computed Tomography/methods , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/standards , Medical Records , Mandibular Condyle , Prevalence , Reproducibility of Results , Radiography, Dental, Digital/methods , Radiography, Panoramic/methods , Sensitivity and Specificity , Temporomandibular Joint Disorders/epidemiology
3.
Braz. oral res ; 28(1): 39-45, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-697001

ABSTRACT

The aim of this study was to use cone-beam computed tomography (CBCT) images to evaluate the prevalence and configurations of C-shaped canals in permanent mandibular second molars among members of a Brazilian subpopulation. CBCT exams of 214 patients (406 teeth) were evaluated for: presence of C-shaped root canals, number of canals and direction of the root grooves (buccal or lingual). Of the 214 CBCT images examined, 192 showed intact bilateral molars, which were used to analyze the distribution of unilateral and bilateral occurrences of C-shaped canals. The prevalence of these canals was correlated with gender and age, and the number of canals was correlated with the direction of the root grooves using the chi-squared test (α = 0.05). The prevalence of C-shaped canals was 15.3%. This prevalence did not differ with gender or age. Most of the C-shaped molars had three (43.5%) or two (37.1%) canals; 69.4% of the C-shaped canals were grooved in the buccal direction; 68.3% of the C-shaped cases were unilateral. In conclusion, there was a significant prevalence of C-shaped canals in the mandibular second molars of the population studied; the C-shaped canal system varied in configuration, with a higher prevalence of three and two canals and unilateral occurrence; CBCT is a useful tool for endodontic diagnosis and treatment.


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Young Adult , Cone-Beam Computed Tomography , Dental Pulp Cavity , Molar , Age Factors , Brazil , Chi-Square Distribution , Dentition, Permanent , Dental Pulp Cavity/anatomy & histology , Molar/anatomy & histology , Sex Factors
4.
Braz. dent. sci ; 17(4): 90-97, 2014. tab, graf
Article in English | LILACS | ID: lil-742512

ABSTRACT

Objective: This study assessed the immediate impact in terms of learning dento-maxillomandibular radiographic anatomy in intraoral periapical radiographs after entire replacement of the method of classroom learning by the distance learning using the Moodle platform. Material and Methods: Teaching of this subject by traditional educational setting in classroom was made until the first semester of 2011, “A class” (AC), using radiographic slabs from duplicated films with imprints indicating anatomical structures in images that is accompanied by textbook with its description and support teacher, who works closely with the classroom to support student learning. In the second semester of 2011, “B class” (BC), these same radiographic slabs were digitalized, including description of textbook, creating the Moodle e-course about dentomaxillomandibular anatomy in intraoral radiographs for distance learning. The impact was assessed by comparison of scores of students from two distinct classes, AC (N = 60) and BC (N = 62), after application of a similar test with all content of the topic of dento-maxillomandibular anatomy, using T-Student unpaired test (α = 0.05). A voluntary and unidentified questionnaire with 12 questions, developed in Google Docs spreadsheets, was used to evaluate the acceptance of students for this e-course. Results: No significant differences (p > 0.05) were observed in scores of the students from two classes. Among other questions, all students of BC who completed the questionnaire had interest in content of the available material in e-course, and their satisfaction level on a scale from 0 to 10 had a mean of 8.47 (SD = 1.69). Conclusion: The method of distance learning of this subject using the Moodle platform can be utilized with same educational results as of those obtained from a traditional educational setting...


Objetivo: Este estudo avaliou o impacto imediato em termos de aprendizagem da anatomia radiográfica dento-maxilo-mandibular em radiografias periapicais intrabucais, após toda a substituição do método de ensino em sala de aula pela educação a distância com a plataforma Moodle. Material e Métodos: O ensino desta disciplina no ambiente educacional tradicional em sala de aula foi feito até o primeiro semestre de 2011, classe A (AC), utilizando pranchas de filmes radiográficos duplicados com marcações que indicavam estruturas anatômicas nas imagens eum livro texto com a descrição da referida estrutura, além de professor de apoio, que trabalhava na sala de aula junto com os alunos como apoio de aprendizagem. No segundo semestre de 2011, para a “classe B” (BC), essas mesmas pranchas radiográficas foram digitalizadas, incluindo a descrição do livro texto, para criar o curso digital Moodle sobre anatomia dentomaxilo- mandibular em radiografias intra-orais para educação a distância. O impacto dessa substituição foi avaliado pela comparação das notas dos alunos dessas duas classes distintas, AC (N= 60) e BC (N = 62), após a aplicação de uma prova semelhante com todo o conteúdo do tema da anatomia dentomaxilo- mandibular, utilizando teste T-Student não pareado (α = 0,05). Um questionário voluntário e não identificado com 12 questões, desenvolvido em planilhas do Google Docs, foi utilizado para avaliar a aceitação dos alunos em relação ao curso digital. Resultados: Não houve diferença significativa (p > 0,05) entre as notas dos alunos das duas classes. Em relação às respostas do questionário, todos os alunos da BC que responderam ao questionário tinham interesse no conteúdo do material disponível no curso digital e o nível de satisfação medido em uma escala de 0 a 10 obteve média de 8,47 (DP = 1,69)...


Subject(s)
Humans , Anatomy, Regional , Education, Distance , Image Interpretation, Computer-Assisted , Radiography, Dental
5.
Braz. dent. j ; 23(6): 703-706, 2012. ilus, tab
Article in English | LILACS | ID: lil-662430

ABSTRACT

The aim of this study was to assess the applicability of gray scale inversion in performing digital linear endodontic measurements. Standardized digital images were taken of 40 extracted human permanent single-rooted teeth with K-files size 15 placed at different lengths in the root canal, using the CDR Wireless® digital system. All images were treated with Positive, a digital tool that inverts the grayscale value. Eight radiologists measured the distance between the lower limit of the rubber stop and the tip of the file on both original and positive images. After 15 days, they repeated this procedure in 50% of the image samples. The intra- and inter-examiner agreement was analyzed by intraclass correlation test, and the comparison between the two image groups and the actual lengths by the Student's t-test (α=0.05). Intra- and inter-examiner evaluation showed high reproducibility (r>0.95) of both original and positive images. No statistically significant differences (p>0.05) were found between measurements performed on original and positive images, but both differed significantly from the actual lengths (p<0.05). Gray scale inversion has low applicability in measuring endodontic files, since it did not improve the accuracy of measurements.


O objetivo deste estudo foi avaliar a aplicabilidade da inversão da escala de cinza na realização de mensurações endodônticas lineares digitais. Quarenta dentes unirradiculares humanos extraídos foram radiografados com limas K tamanho 15 posicionadas no canal radicular em diferentes comprimentos, usando o sistema digital CDR Wireless®. Todas as imagens foram tratadas com Positive, uma ferramenta digital que inverte os valores da escala de cinza. Oito radiologistas mediram a distância entre o limite inferior do stop de borracha e a ponta da lima endodôntica nas imagens originais e positivas. Após quinze dias, eles repetiram esse procedimento em 50% da amostra. A concordância intra- e interobservador foi analisada pelo teste de correlação intraclasse e a comparação entre os dois grupos de imagem e os valores reais, pelo teste t-Student (α=0,05). A análise intra- e interobservador apresentou elevada reprodutibilidade (r>0,95) das imagens original e Positive. Não foi encontrada diferença (p>0,05) entre as medidas realizadas nas imagens original e positiva, mas ambas diferiram dos valores reais (p<0,05). A inversão da escala de cinza tem baixa aplicabilidade na realização de mensuração endodôntica, considerando que as medidas não se apresentaram mais acuradas.


Subject(s)
Humans , Dental Pulp Cavity , Odontometry/methods , Radiography, Dental, Digital/methods , Tooth Apex , Dental Pulp Cavity/anatomy & histology , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/statistics & numerical data , Observer Variation , Odontometry/statistics & numerical data , Phantoms, Imaging , Reproducibility of Results , Radiography, Dental, Digital/statistics & numerical data , Root Canal Preparation/instrumentation , Software , Tooth Apex/anatomy & histology
6.
Braz. dent. j ; 22(2): 129-133, 2011. tab
Article in English | LILACS | ID: lil-583801

ABSTRACT

The aim of this study was to evaluate the accuracy on the diagnosis of secondary caries-like lesions simulated on esthetic restorations of different materials, changing the incidence vertical angle (IVA) of the x-ray beam. Twenty human teeth received MOD inlay preparations. In the experimental group (n=10), a round cavity was made in the floor of the proximal box to simulate the caries-like lesion. All teeth were restored with 3 composite resins (Charisma, Filtek-Z250 and TPH-Spectrum) at 3 moments. Two radiographic images were acquired with 0º and 10º IVA. Ten observers evaluated the images using a 5-point confidence scale. Intra- and interobserver reliability was analyzed with the Interclass Correlation Coefficient and the diagnostic accuracy was evaluated using the area under the ROC curve (Az), Friedman test and Wilcoxon test (α=0.05). Higher accuracy values were obtained with 10º IVA (Az=0.66, Filtek-Z250>Az=0.56, TPH-Spectrum) compared to 0º (Az=0.55, Charisma>Az=0.37, TPH-Spectrum), though without statistically significant difference (p>0.05). The detection of secondary caries-like lesions simulated on esthetic restorations of different materials suffered no negative influence by changing the IVA of the x-ray beam.


O objetivo deste estudo foi avaliar a precisão no diagnóstico de lesões iguais-à-cárie secundárias simuladas em restaurações estéticas de materiais diferentes, mudando o ângulo vertical de incidência (AVI) do feixe de raios-x. Vinte dentes humanos foram submetidos a preparo cavitário inlay MOD. No grupo experimental (n=10), no soalho da caixa de proximal, foi confeccionada uma cavidade esférica para simular lesões iguais-a-cárie. Todos os dentes foram restaurados com 3 resinas compostas (Charisma, Filtek-Z250, TPH-Spectrum), em três tempos diferentes. Duas imagens radiográficas foram adquiridas com 0 e 10 graus de AVI o feixe de raios-x. Dez observadores avaliaram as imagens usando uma escala de confiança de 5-pontos. A reprodutibilidade intra- e inter- observador foi analisada com o coeficiente de correlação interclasse e a precisão do diagnóstico foi avaliada usando a área sob a curva ROC (Az), o teste de Friedman e de Wilcoxon (α=0,05). Os mais altos valores de precisão (p>0,05) foram observados com o AVI em 10º (Filtek-Z250 Az=0,66>TPH-Spectrum Az=0,56) comparado com 0º (Charisma Az=0,55>TPH-Spectrum Az=0,37), porém, sem diferenças estatisticamente significantes (p>0,05). A detecção de lesões iguais-à-cárie secundárias simulada em restaurações estéticas de diferentes materiais não foi influenciada pela mudança de AVI do feixe de raios-x.


Subject(s)
Humans , Dental Caries , Dental Restoration, Permanent/adverse effects , Radiography, Bitewing/methods , Chi-Square Distribution , Composite Resins , Dental Caries/etiology , Dental Restoration, Permanent/methods , Esthetics, Dental , Observer Variation , ROC Curve , Statistics, Nonparametric
7.
Braz. dent. j ; 21(5): 458-462, 2010. ilus, tab
Article in English | LILACS | ID: lil-568993

ABSTRACT

The aim of this study was to determine size, shape and position of the image layer by evaluation of the radiographic image formation in different anatomic positions. A customized phantom was made of a rectangular acrylic plate measuring 14 cm² and 0.3 cm thick, with holes spaced 0.5 cm away and arranged in rows and columns. Each column was separately filled with 0.315 cm diameter metal spheres to acquire panoramic radiographs using the Orthopantomograph OP 100 unit. The customized phantom was placed on the mental support of the device, with its top surface kept parallel to the horizontal plane, and was radiographed at three different heights from the horizontal plane, i.e., the orbital, occlusal and mandibular symphysis levels. The images of the spheres were measured using a digital caliper to locate the image layer. The recorded data were analyzed statistically by the Student'-t test, ANOVA and Tukey' test (?=0.05). When the image size of spheres in horizontal and vertical axes were compared, statistically significant differences (p<0.05) were observed in all areas, portions of the image layer and heights of horizontal plane evaluated. In the middle portion of the image layer, differences in the image size of spheres were observed only along the horizontal axis (p<0.05), whereas no differences were observed along the vertical axis (p>0.05). The methodology used in this determined the precise size, shape and position of the image layer and differences in magnification were observed in both the horizontal and vertical axes.


O objetivo na presente pesquisa foi determinar o tamanho, forma e posição da camada de imagem por meio da avaliação da formação da imagem radiográfica em diferentes posições anatômicas. Foi construído um phantom constituído por uma placa acrílica de 14 cm² e 0,3 cm de espessura, com sua superfície contendo perfurações a cada 0,5 cm dispostas em linhas e colunas. O phantom foi posicionado no local do apoio de mento do aparelho panorâmico, com sua superfície paralela ao plano horizontal. Esferas metálicas de 0,315 cm foram inseridas nas perfurações, e executadas radiografias panorâmicas. Cada coluna de cada quadrante foi individualmente preenchida pelas esferas para a execução das radiografias, em três planos horizontais diferentes: alturas orbital, oclusal e mentual. As imagens das esferas foram medidas com o uso de um paquímetro digital e a camada de imagem localizada. Os dados foram analisados estatisticamente utilizando-se o teste T Student, ANOVA e teste de Tukey (?=0,05). Quando o tamanho das esferas nos eixos horizontal e vertical foi comparado, diferenças estatisticamente significativas (p<0,05) foram observadas em todas as áreas da camada de imagem, porções e alturas do plano horizontal avaliado. Na porção central da camada de imagem diferenças no tamanho das esferas foram observadas somente no eixo horizontal (p<0,05), enquanto que no eixo vertical nenhuma diferença foi observada (p>0,05). A metodologia utilizada determinou com precisão o tamanho, forma e posição da camada de imagem, e diferenças de ampliação foram observadas tanto no eixo horizontal quanto vertical.


Subject(s)
Humans , Radiographic Image Enhancement/methods , Radiography, Panoramic/methods , Equipment Design , Fiducial Markers , Mandible , Orbit , Phantoms, Imaging , Radiographic Magnification , Tooth
8.
Braz. oral res ; 22(1): 78-83, Jan.-Mar. 2008. ilus, tab
Article in English | LILACS | ID: lil-480588

ABSTRACT

This study aimed at investigating the effect of the partial erasing of DenOptix® system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix® storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszel’s chi-square test, at a significance level of 5 percent, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30 percent) versus 130 seconds (70 percent), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix® storage phosphor plates may require time intervals of as little as 5 seconds.


Subject(s)
Radiographic Image Enhancement/standards , Radiographic Magnification/standards , Radiography, Dental, Digital/standards , Chi-Square Distribution , Image Processing, Computer-Assisted , Light , Luminescent Measurements , Phantoms, Imaging , Radiographic Image Enhancement/methods , Radiographic Magnification/methods , Radiography, Dental, Digital/methods , Software , Time Factors , X-Ray Intensifying Screens
9.
Braz. dent. j ; 18(3): 208-214, 2007. ilus, tab
Article in English | LILACS | ID: lil-471442

ABSTRACT

The aim of this study was to assess the effect of low-dose electron irradiation on morphological features of the wound healing process in rat skin. Surgical wounds were inflicted with a 2.3 x 1.4 cm template on 84 male rats that were assigned to 4 groups: IG1, immediately irradiated; IG2, irradiated 3 days after inflicting the wound; CG1 and CG2, control groups. Rats in IG1 and IG2 groups had their wounds exposed to 1 Gy of 6 MeV electron beam radiation, immediately after surgery and on the third postoperative day, respectively. Qualitative and histophotometric evaluations of tissue repair structures were carried out. Data were analyzed by ANOVA and Tukey's test (alpha = 0.05) and regression analysis. The repair process was delayed since the first sacrifice time in both irradiated groups, but in IG1, wound healing was closer to that of CG1; whereas in IG2, the delay was more pronounced. Based on the histological findings, it is possible to conclude that a low-dose of electron radiation delayed tissue repair in rat skin. The delay was longer in the skin irradiated 3 days after the beginning of tissue repair. However, the low-energy electron irradiation did not prevent wound healing.


O objetivo deste estudo foi avaliar o efeito da irradiação por baixa dose de elétrons sobre características morfológicas da reparação tecidual na pele de rato. Foram realizadas feridas cirúrgicas com um gabarito de 2,3 x 1,4 cm em 84 ratos machos, divididos em 4 grupos: IG1, irradiado imediatamente; IG2, irradiado 3 dias após a produção da ferida; CG1 e CG2, grupos controles. Os ratos dos grupos IG1 e IG2 tiveram suas feridas expostas a 1 Gy de radiação por elétrons com 6 MeV, imediatamente após a cirurgia e ao terceiro dia pós-operatório, respectivamente. Procedeu-se às avaliações qualitativas e histofotométrica das estruturas de reparação tecidual. Os dados foram submetidos a ANOVA e teste Tukey (a = 0,05) e análise de regressão. O processo de reparação apresentou-se atrasado desde o primeiro tempo de sacrifício em ambos os grupos irradiados, mas para IG1, a reparação tecidual foi similar a CG1. Por outro lado, para IG2, o retardo foi mais pronunciado. Com base nas avaliações histológicas, é possível concluir que uma baixa dose de radiação por elétrons retardou a reparação na pele de rato. O atraso foi maior na pele irradiada 3 dias após o início da reparação tecidual. No entanto, esta irradiação por elétrons de baixa energia não impediu a cicatrização.


Subject(s)
Animals , Male , Rats , Beta Particles , Glycosaminoglycans/radiation effects , Granulation Tissue/radiation effects , Skin/radiation effects , Wound Healing/radiation effects , Dose-Response Relationship, Radiation , Glycosaminoglycans/metabolism , Granulation Tissue/metabolism , Radiation Dosage , Rats, Wistar , Skin/metabolism , Skin/surgery , Time Factors , Wound Healing/physiology
10.
Rev. Assoc. Paul. Cir. Dent ; 60(5): 357-360, set.-out. 2006. tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-543814

ABSTRACT

O objetivo neste estudo foi comparar a precisão das imagens radiográficas realizadas com posicionadores de três diferentes marcas: Rinn XCP utilizando localizador curto e longo, Hanshin e lndusbello com localizador curto. As médias das medidas radiográficas foram calculadas e comparadas com o tamanho original dos dentes. Os resultados foram submetidos à análise de variância e ao teste de Tukey com a=0,05. Todos os posicionadores analisados ampliaram o tamanho da imagem sendo que o da Rinn XCP com localizador longo promoveu a menor ampliação. Não houve diferença estatisticamente significativa entre Rinn XCP com localizador longo e Hanshin. Os posicionadores da técnica da bissetriz e do paralelismo, quando utilizados com as distâncias recomendadas, possibilitaram a obtenção de mensurações dentárias próximas ao tamanho real.


The objective with this work was to compare the radiographic images precision of the dental elements accomplished with film holders of three different brand: RINN XCP used short and long beam-indicating devices, HANSHIN and INDUSBELLO used short beam-indicating devices. The mean measurements of radiographic image were calculated and compared with the teeth length size. All the film holders analyzed promoted the magnified radiographic and the RINN XCP's film holders with long beam indicating device promoted the minor magnified. No significant differences were found among RINN XCP's film holders with long beam-indicating device and HANSHIN. The film holders for the parallel and bisecting-the-angle technique when used with the recommended distances make possible to obtain radiographic image measurements close tooth length size.


Subject(s)
Humans , Diagnostic Imaging , Radiographic Magnification , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL